A custom adapter is a controlled interface between two systems. Quote it by defining both connections, the sealing method, clocking, material grade, finish, cleanliness and gauge requirements.

The article focuses on the adapter as an interface-control problem rather than repeating a generic stainless-grade guide. The useful outcome is a controlled specification that lets engineering, purchasing, manufacturing and quality make the same decision.
Decision table
| Control point | Define in the RFQ | Risk if omitted |
|---|---|---|
| End A / End B | Complete interface callout for each end | One side is assumed from a sample |
| Orientation | Clocking between flats, ports or elbows | Assembly points in the wrong direction |
| Material | Exact grade and permitted substitutions | Corrosion or certification mismatch |
| Traceability | Part/revision marking and lot records | Repeat orders cannot be reconciled |

Treat each end as its own specification
List thread standard, size, class, depth, gauge and sealing feature for both connections. For mixed standards, add a section view so no one infers the transition from the title.
Buyer action: Add the related requirement, acceptance method and responsible party to the RFQ or drawing clarification log. Do not leave it as an unwritten assumption.
Decide how the part will be held and tightened
Wrench flats, hex size, tool clearance and installation envelope affect machining and field use. If orientation matters at torque, state the acceptable angular window and test method.
Buyer action: Add the related requirement, acceptance method and responsible party to the RFQ or drawing clarification log. Do not leave it as an unwritten assumption.
Select the finish around function
Passivation can support stainless cleanliness and corrosion performance; electropolishing also changes surface topography. Specify a standard and acceptance test when required instead of requesting an undefined “medical finish.”
Buyer action: Add the related requirement, acceptance method and responsible party to the RFQ or drawing clarification log. Do not leave it as an unwritten assumption.
Approve a repeatable control plan
For recurring orders, record material heat/lot identification, gauge status, first-article results, finish batch and packaging method. A golden sample alone is not a complete specification.
Buyer action: Add the related requirement, acceptance method and responsible party to the RFQ or drawing clarification log. Do not leave it as an unwritten assumption.
How to compare supplier responses
Do not score a supplier by how quickly it returns a price. Score the response by how many technical and commercial assumptions it closes. A strong quotation identifies the released inputs, exclusions, substitutions, one-time charges, recurring price and first-shipment evidence.
Use the same comparison sheet for every bidder: price basis, quantity, material, route, finish, inspection, documentation, packaging, delivery term, lead-time start and quotation validity. Resolve scope differences before negotiating price.
End A / End B: ask for objective evidence
The quotation should state complete interface callout for each end. If it does not, ask how the supplier will prevent one side is assumed from a sample, which document records acceptance, and what happens when the result is outside the requirement. A useful answer names the process owner, inspection or review method, frequency and record—not only a quality promise.
Orientation: ask for objective evidence
The quotation should state clocking between flats, ports or elbows. If it does not, ask how the supplier will prevent assembly points in the wrong direction, which document records acceptance, and what happens when the result is outside the requirement. A useful answer names the process owner, inspection or review method, frequency and record—not only a quality promise.
Material: ask for objective evidence
The quotation should state exact grade and permitted substitutions. If it does not, ask how the supplier will prevent corrosion or certification mismatch, which document records acceptance, and what happens when the result is outside the requirement. A useful answer names the process owner, inspection or review method, frequency and record—not only a quality promise.
Traceability: ask for objective evidence
The quotation should state part/revision marking and lot records. If it does not, ask how the supplier will prevent repeat orders cannot be reconciled, which document records acceptance, and what happens when the result is outside the requirement. A useful answer names the process owner, inspection or review method, frequency and record—not only a quality promise.

RFQ checklist
- Controlled part number, drawing revision, units and 3D model
- Exact material grade/condition and certificate requirement
- Critical dimensions, threads, sealing faces and datums
- Surface treatment and post-finish acceptance
- Prototype/batch quantities, destination and delivery term
- Inspection, test, traceability and reporting
- Packaging and repeat-order expectations
Practical buyer scenario
A buyer receives two quotes for the same nominal part. One is cheaper but lists only material and unit price. The second states the drawing revision, manufacturing route, treatment, critical inspection, sample approval and delivery basis. Normalize scope, close technical questions and compare cost per accepted part—not a headline price built on missing assumptions.

Frequently asked questions
Can I quote from an existing adapter sample?
Yes for feasibility, but production should use a measured and approved drawing with confirmed thread and material requirements.
Should the supplier choose 304 or 316?
Provide the grade or a documented substitution process. The application owner must decide corrosion and compliance needs.
How is clocking inspected?
Define reference features, tightening condition and angular acceptance on the drawing or inspection instruction.
What finish should I request?
Name the process, applicable standard, cosmetic boundary and any verification such as free-iron or corrosion testing.
Sources and standards references
- KEC Tour — custom metal parts and non-standard hardware
- ASME B1.20.1 — Pipe Threads, General Purpose, Inch
- ISO 7-1 — Pipe threads where pressure-tight joints are made on the threads
- ASTM A967/A967M-25 — Chemical passivation of stainless-steel parts
- ASTM B912-26 — Passivation of stainless steels using electropolishing
Engineering note: confirm the standard edition, customer specification and regulatory obligations for the actual part. KEC Tour provides manufacturing and DFM input; the buyer retains product-design and application-validation responsibility.
Related engineering guides
Have a custom metal part to manufacture?
Send the controlled drawing, sample or photo plus material, quantity, finish and inspection needs.
Turn your requirements into a production-ready RFQ.
Share your CAD file, material, critical dimensions, finish and target volume. KEC Tour will review the process route before quoting.